Get started
ClinicalLive · in the productClinical record

IHCTrack

IHC and special stains per block: antibody lot, controls, scores, and onto the case report.

Installs with SpecimenTrack and LabBridge, whose screen it works on
Get IHCTrackOpen the appAvailable nowHow pricing works →

What it is

Immunohistochemistry and special stains, from the block to the signed report. The blocks come from the specimen’s grossing in SpecimenTrack (A1, A2 and so on, never more than the grossing counted). Ask for a marker panel on one block, such as ER, PR, HER2 and Ki-67 for a breast core. The lab cuts a slide per marker and records each stain run with the antibody lot (picked from LotWatch, where an expired lot is refused) and the positive and negative control. A run whose control failed blocks the read: the slide cannot be scored until a fresh one is cut and stained with both controls passing, and every run stays on record. The pathologist scores each marker in its own system (Allred for ER and PR, 0 to 3+ for HER2, a percentage for Ki-67, positive or negative for a special stain), and the scores go onto the case’s LabBridge report: as an addendum, a new signed version that says what was added, when the report is already signed, or as lines on the report still being written.

Who uses it
Built for: Diagnostics & Labs
Reads
Specimens, grossing and blocks, antibody lots in LotWatch, the case’s lab report
Writes
IHC requests and marker panels, slides cut and stain runs with their controls, scores, and an addendum on the signed report
Never
It never scores a slide whose last stain failed a control, never signs a report by itself, and never edits a signed report: an addendum is a new version that says what changed.
Access
Only people whose role includes it — the clinic owner decides who
Your data
Full PHI. Hosted in Boston, United States. On uninstall: Requests, runs and scores stay on record, and scores already on a report stay there. Blocks and slides stay in SpecimenTrack.

How it works

  1. Ask for a panel on a blockPick the specimen and block, and the markers: ER, PR, HER2, Ki-67, or a special stain.
  2. Cut, stain, check the controlsRecord the antibody lot and both controls for each run. A failed control means a fresh slide.
  3. Score and add to the reportScore each marker in its own system; the scores go onto the case report as an addendum.

Rules it keeps

What it does not do, by design. A listing with only benefits is an advertisement.

It never scores a slide whose last stain failed a control, never signs a report by itself, and never edits a signed report: an addendum is a new version that says what changed.

AI in IHCTrack

AskQuestions about what is on screen — “What needs attention in IHCTrack today?” — answered with the records it read.
DraftSummaries and notes for the team, marked as drafts until a person signs.
Every answer shows its sources. Nothing AI writes is saved until a person accepts it.

See it on screen

Live product
01IHC & Stains — Track IHC and special stains per block, with lots and controls, onto the reportCaptured from the running demo clinic
IHCTrack — IHC & Stains — Track IHC and special stains per block, with lots and controls, onto the report
1 of 1

Connected to

Read out of the code, not the brochure: each app below is here because one service queries the other’s tables. Install either side and the hand-over is already wired.

Hands to · 1
See the whole clinic →

Questions clinics ask

What does IHCTrack do?
IHC and special stains per block: antibody lot, controls, scores, and onto the case report. Immunohistochemistry and special stains, from the block to the signed report. The blocks come from the specimen’s grossing in SpecimenTrack (A1, A2 and so on, never more than the grossing counted). Ask for a marker panel on one block, such as ER, PR, HER2 and Ki-67 for a breast core. The lab cuts a slide per marker and records each stain run with the antibody lot (picked from LotWatch, where an expired lot is refused) and the positive and negative control. A run whose control failed blocks the read: the slide cannot be scored until a fresh one is cut and stained with both controls passing, and every run stays on record. The pathologist scores each marker in its own system (Allred for ER and PR, 0 to 3+ for HER2, a percentage for Ki-67, positive or negative for a special stain), and the scores go onto the case’s LabBridge report: as an addendum, a new signed version that says what was added, when the report is already signed, or as lines on the report still being written.
What data does IHCTrack read and write?
IHCTrack reads specimens, grossing and blocks, antibody lots in LotWatch, the case’s lab report and writes IHC requests and marker panels, slides cut and stain runs with their controls, scores, and an addendum on the signed report. Its data class is Full PHI. Every app works on the same patient record — nothing is copied into a silo.
What does IHCTrack deliberately not do?
It never scores a slide whose last stain failed a control, never signs a report by itself, and never edits a signed report: an addendum is a new version that says what changed.
What happens to our data if we uninstall IHCTrack?
Requests, runs and scores stay on record, and scores already on a report stay there. Blocks and slides stay in SpecimenTrack.
Is IHCTrack available today?
Yes — IHCTrack is live in clinics today. Set up your practice on MedAppz and install it from your dashboard.

Want to see IHCTrack running on your own patients?

Tell us what you run and we will show you this app inside a practice shaped like yours — or answer the question the page above did not.

We use your name, phone number and clinic name for one thing: to answer this enquiry about MedAppz. It is stored on our own server, in the single region our trust centre names, and it is not sold or passed to anyone else.

Email us

You can withdraw either at any time: write to hello@medappz.com, or tell whoever calls you, and we will delete what you gave us.

More in Clinical

All 406 →
Featured inPathology & Laboratory