AutoVerify

Normal results released by the lab’s own validated rules; criticals, delta failures and QC lockouts always wait for the pathologist.

Installs with LabBridge, whose screen it works on

What it is

The lab writes its release rules per test, with a lab default for the rest: release a value inside its reference range (or a narrower window per analyte), with no analyser or sample-quality flag, an accepted QC run on the analyte recently enough, and — if the lab says so — only for a patient who has had the test before. Four holds no rule can switch off: a critical value, a DeltaCheck failure, a QC lockout and a value with no reference range. Everything held waits in the pathologist’s queue with the reason in plain words, criticals first and then by turnaround time, for a one-tap verify and sign; routine holds can be signed together, the four hard holds only one by one. A new rule set starts in shadow mode, deciding without releasing, and the screen shows how often it agreed with the pathologist and how many results it would have released that the pathologist then changed — that number must be 0 before going live. Released results are signed in the duty pathologist’s name, and every release keeps the rule version and the inputs it was judged on. A version that has released anything is never edited: a change becomes the next version. Every critical value opens a call-back: who to call and their number, each attempt logged, closed only when someone reads the value back, and escalated when nobody is reached in time.

Who uses it
Built for: Every specialty
Reads
Resulted lab orders and their values, ranges and flags, DeltaCheck flags and QCBench runs and lockouts, the ordering doctor, ward and patient phone for a call-back
Writes
Each decision: released or held, why, the rule version and the inputs, the signed report, through LabBridge, in the duty pathologist’s name, critical call-backs, every call attempt and the read-back
Never
It never releases a critical value, a delta failure, a result from a QC lockout or a value with no reference range, never changes a rule version that has released a result, and never closes a critical call-back without a read-back.
Access
Only people whose role includes it — the clinic owner decides who
Your data
Full PHI. Hosted in Boston, United States. On uninstall: Rules stop releasing and every result waits for the pathologist again. Decisions, rule versions and call-back logs are kept as the audit.

How it works

  1. Write the rules and run them in shadowPer test or a lab default. In shadow mode they decide but never release, and each decision is checked against what the pathologist did.
  2. Go live when unsafe is 0Pick the duty pathologist and switch to live. Normal results release in their name; everything else lands in the held queue with the reason.
  3. Clear the held queue and the call-backsVerify and sign each held result, routine ones together. Call each critical, log who you reached and that they read it back.

Rules it keeps

What it does not do, by design. A listing with only benefits is an advertisement.

It never releases a critical value, a delta failure, a result from a QC lockout or a value with no reference range, never changes a rule version that has released a result, and never closes a critical call-back without a read-back.

AI in AutoVerify

AskQuestions about what is on screen — “What needs attention in AutoVerify today?” — answered with the records it read.
DraftSummaries and notes for the team, marked as drafts until a person signs.
Every answer shows its sources. Nothing AI writes is saved until a person accepts it.

See it on screen

Live product
01Auto Verify — Release normal results by your own rules; criticals always wait for the pathologistCaptured from the running demo clinic
AutoVerify — Auto Verify — Release normal results by your own rules; criticals always wait for the pathologist
1 of 1

Connected to

Read out of the code, not the brochure: each app below is here because one service queries the other’s tables. Install either side and the hand-over is already wired.

Hands to · 1
See the whole clinic →

Questions clinics ask

What does AutoVerify do?
Normal results released by the lab’s own validated rules; criticals, delta failures and QC lockouts always wait for the pathologist. The lab writes its release rules per test, with a lab default for the rest: release a value inside its reference range (or a narrower window per analyte), with no analyser or sample-quality flag, an accepted QC run on the analyte recently enough, and — if the lab says so — only for a patient who has had the test before. Four holds no rule can switch off: a critical value, a DeltaCheck failure, a QC lockout and a value with no reference range. Everything held waits in the pathologist’s queue with the reason in plain words, criticals first and then by turnaround time, for a one-tap verify and sign; routine holds can be signed together, the four hard holds only one by one. A new rule set starts in shadow mode, deciding without releasing, and the screen shows how often it agreed with the pathologist and how many results it would have released that the pathologist then changed — that number must be 0 before going live. Released results are signed in the duty pathologist’s name, and every release keeps the rule version and the inputs it was judged on. A version that has released anything is never edited: a change becomes the next version. Every critical value opens a call-back: who to call and their number, each attempt logged, closed only when someone reads the value back, and escalated when nobody is reached in time.
What data does AutoVerify read and write?
AutoVerify reads resulted lab orders and their values, ranges and flags, DeltaCheck flags and QCBench runs and lockouts, the ordering doctor, ward and patient phone for a call-back and writes each decision: released or held, why, the rule version and the inputs, the signed report, through LabBridge, in the duty pathologist’s name, critical call-backs, every call attempt and the read-back. Its data class is Full PHI. Every app works on the same patient record — nothing is copied into a silo.
What does AutoVerify deliberately not do?
It never releases a critical value, a delta failure, a result from a QC lockout or a value with no reference range, never changes a rule version that has released a result, and never closes a critical call-back without a read-back.
What happens to our data if we uninstall AutoVerify?
Rules stop releasing and every result waits for the pathologist again. Decisions, rule versions and call-back logs are kept as the audit.
Is AutoVerify available today?
Yes — AutoVerify is live in clinics today. Set up your practice on MedAppz and install it from your dashboard.

Want to see AutoVerify running on your own patients?

Tell us what you run and we will show you this app inside a practice shaped like yours — or answer the question the page above did not.

We use your name, phone number and clinic name for one thing: to answer this enquiry about MedAppz. It is stored on our own server, in the single region our trust centre names, and it is not sold or passed to anyone else.

Email us

You can withdraw either at any time: write to hello@medappz.com, or tell whoever calls you, and we will delete what you gave us.

More in Clinical

All 437 →
Featured inDiagnostics QA stack