Get started
ComplianceLive · in the productRegister

SteriLog

CSSD cycles with load traceability.

Installs with TrayTrace, whose screen it works on
Get SteriLogOpen the appAvailable nowHow pricing works →

What it is

Sterilisation loads with cycle parameters, indicators and release signatures — traceable from tray to patient case.

Who uses it
Built for: Every specialty
Reads
Cycle data, cases
Writes
Load records, releases
Never
It will not release a load with a failed indicator, whoever asks.
Access
Only people whose role includes it — the clinic owner decides who
Your data
No PHI. Hosted in Boston, United States. On uninstall: Operational history stays queryable for audit.

How it works

  1. Register the steriliserEach autoclave, plasma or EtO machine is registered by name, and its cycles are numbered per machine.
  2. Start the cycleStart cycle opens a numbered cycle on that steriliser; trays are packed onto it before it runs, and a retired machine takes none.
  3. Record the three indicatorsRecord result takes the physical and chemical indicators as ticks and the biological indicator as pending, pass or fail — results go on a pending cycle only.
  4. Release only what the indicators earnedRelease is refused unless the BI passed and both the physical and chemical indicators are ok, held by a CHECK as well as the guarded update.
  5. Recall a released cycleRecall (BI failure) quarantines every tray of that cycle in one update, in the same transaction, stamped on the cycle — and only a released cycle can be recalled.

Rules it keeps

What it does not do, by design. A listing with only benefits is an advertisement.

It will not release a load with a failed indicator, whoever asks.

AI in SteriLog

AskQuestions about what is on screen — “What needs attention in SteriLog today?” — answered with the records it read.
DraftSummaries and notes for the team, marked as drafts until a person signs.
Every answer shows its sources. Nothing AI writes is saved until a person accepts it.

See it on screen

Live product
01CSSD — Log sterilisation cycles, traceable to each patientCaptured from the running demo clinic
SteriLog — CSSD — Log sterilisation cycles, traceable to each patient
1 of 1

Connected to

Read out of the code, not the brochure: each app below is here because one service queries the other’s tables. Install either side and the hand-over is already wired.

Reads from · 1
Hands to · 1
See the whole clinic →

Questions clinics ask

What does SteriLog do?
CSSD cycles with load traceability. Sterilisation loads with cycle parameters, indicators and release signatures — traceable from tray to patient case.
What data does SteriLog read and write?
SteriLog reads cycle data, cases and writes load records, releases. Its data class is No PHI. Every app works on the same patient record — nothing is copied into a silo.
What does SteriLog deliberately not do?
It will not release a load with a failed indicator, whoever asks.
What happens to our data if we uninstall SteriLog?
Operational history stays queryable for audit.
Is SteriLog available today?
Yes — SteriLog is live in clinics today. Set up your practice on MedAppz and install it from your dashboard.

Want to see SteriLog running on your own patients?

Tell us what you run and we will show you this app inside a practice shaped like yours — or answer the question the page above did not.

We use your name, phone number and clinic name for one thing: to answer this enquiry about MedAppz. It is stored on our own server, in the single region our trust centre names, and it is not sold or passed to anyone else.

Email us

You can withdraw either at any time: write to hello@medappz.com, or tell whoever calls you, and we will delete what you gave us.

More in Compliance

All 140 →